Adapting the machine to the remote PC
1. In the "Start-up" area press the "ETC" key (">").
2. Press the "Remote Diagnosis" softkey. The following window appears:
Figure 8-5
● The port number, default 5800, is entered in the "Port for remote diagnosis (default
Option: "RCS service partner operates a Ping server" selected
By selecting the option "RCS service partner operates a Ping server", the remote PC is
triggered to operate a Ping server. The following settings must be obtained from the service
partner operating a ping server:
● Ping server port
● Png server IP address of the "Ping" server is running
● Protocol selection, UDP or TCP/IP
● Connection duration (min): Entry for the maximum time for the duration of the remote
● Transmission interval (sec): The Ping data is transmitted cyclically in this interval from the
● Ping transmission data: Entry of an agreed user data string
Commissioning HMI-Embedded (IM2)
Commissioning Manual, 01/2008, 6FC5397-8CP10-1BA0
8.5 Remote diagnosis "RCS Host Embedded / RCS Viewer Embedded"
Setting up logon server
5800)" input field for the server process (remote diagnosis). The same port number must
be entered in the "Viewer" application on the remote PC.
diagnosis. After this time expires, the connection is interrupted.
NCU 7x0 to the remote PC. This is used for the monitoring of the connection.