LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Additional measures must be taken before storage and on commissioning to
preserve proper functioning – irrespective of the storage time which may be
longer than the warranty period of our products. However, this does not
involve any additional warranty claims.
Motors
Bearing time / months
Measures for commissioning
> 1
< 24
> 24
Control all parts to be free of damage.
Check all electrical contacts to be free from corrosion.
Manually turn the motor shaft in regular distances (min. 1x per
year) to spread the grease consistently.
Running in the motor without load at startup.
Additonally, in the case of a storage time of more than 2 years,
change the motor bearings.
Tab. 6-7:
Measures before commissioning motors that have been stored over a
prolonged period of time
Cables and Connectors
Bearing time / months
Measures for commissioning
> 1
> 12
> 60
Control all parts to be free of damage.
Check all electrical contacts to be free from corrosion.
Visually inspect the cable jacket. Do not use the cable if you de‐
tect any abnormalities (squeezed or kinked spots, color devia‐
tions, ...).
Tab. 6-8:
Measure before commissioning cables and connectors that have been
stored over a prolonged period of time
PGx
Bearing time / months
Measures for storage
< 9
< 24
> 24
Let the internal gear pump in its delivery state (moistened with
mineral oil)
Fill the internal gear pump with mineral oil
Measures for commissioning
Before mounting, check the complete internal gear pump for dam‐
age and corrosion.
At a test run, check the internal gear pump for functionality and
leakproofness.
Change the shaft sealing ring.
After the maximum storage time (24 months) we recommend a
preventive check of the internal gear pump with change of the
sealings by the responsible Rexroth service!
Tab. 6-9:
Measures for storage and before commissioning internal gear pumps
that have been stored over a prolonged period of time