Bosch Rexroth Sytronix FcP 50 Series Operating Instructions Manual page 48

Motor-pump unit mpes2
Table of Contents

Advertisement

46/143
Bosch Rexroth AG
Transport and Storage
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Rexroth Sytronix FcP 50xx/70xx Motor-Pump Unit MPES2
A10VZO/A4VSO
Bearing time / months
Measures for storage
< 12
< 24
> 24
Coat the inner side of the axial piston unit with mineral oil by filling
in approx. 100 ml mineral oil.
Fill in anticorrosion agents VCI 329 (20 ml) into the axial piston
unit.
1. Filling must be done via the tank connection L or L1, refer to
Rexroth Sytronix, Assembly and Commissioning, Axial Piston
Variable Pump A10VZO/A10VSO/A4VSO, material number:
R911341628.
2. Hermetically seal all connections.
3. Coat all unpainted surfaces of the axial piston pump with miner‐
al oil.
4. or suitable, easy to remove anticorrosion agents, e.g. acid-free
grease.
5. Hermetically pack the axial piston pump and a drying agent into
anticorrosion foil.
6. Store the axial piston pump shockproof.
Measures for commissioning
Before mounting, check the complete axial piston pump for dam‐
age and corrosion.
At a test run, check the axial piston pump for functionality and
leakproofness.
Change the shaft sealing ring.
After the maximum storage time (24 months) we recommend a
preventive check of the axial piston pump by the responsible
Rexroth service!
Tab. 6-10:
Measures for storage and before commissioning axial piston pumps
that have been stored over a prolonged period of time
DOK-SYTROX-MPES2******-IT01-EN-P