Rexroth Sytronix FcP 50xx/70xx Motor-Pump Unit MPES2
8.2.2

Power Connection

Connection Power Cables
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Ensure that the terminal box is clean and dry. Seal not used cable ducts. Be‐
fore re-assembly, check the position and correct seat of the terminal box
sealing.
To connect the motor, use a specified power cable. This must be ordered and
assembled by the customer.
1. First, determine the correct wire lengths. Therefore, open the terminal
box and remove the protective cap of the cable gland.
2. Insert the cable through the cable gland up to the furthermost terminal.
Mark the cable on the entry within the terminal box.
3. Pull out the cable of the terminal box and remove the cable jacket up to
this mark.
4. The exposed cable shield must be split acc. to chapter
nection Total Shield Power Cables" on page
steps about shield assembly can be done immediately or after this pro‐
cedure.
5. The now accessible wires are fastened with ring terminals on the termi‐
nal stud. Strip the wires according to the size of ring terminals. The size
of ring terminal depends on the diameter of the terminal stud. For diam‐
eter of the terminal stud and tightening torques refer to data sheet of the
motor under
chapter 1.2 "Necessary and Supplementary Documenta‐
tion" on page
15.
A
Terminal boxes up to frame size 132
B
Terminal boxes from frame size 160
Fig. 8-2:
Preparing power connection
Bosch Rexroth AG
67/143
Connection
chapter "Con‐
68. All further working