Mitsubishi Electric MELSEC Q Series Reference Manual page 351

Q corresponding melsecnet/h network system
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

APPENDICES
No.
Name
3
Remote sub-master
SB0076
station cyclic transmission
(118)
status
3
Remote master station
SB0077
cyclic transmission control
(119)
status
3
Parameter
SB0078
communication status of
(120)
each station
3
SB007A
(122)
Low-speed cyclic
communication status
3
SB007B
(123)
3
Parameter status of each
SB007C
station
(124)
3
5
CPU operation status of
SB0080
each station (1)
(128)
3: Valid only when SB0047 is off. When it turns on (error), the last data are retained.
5: Serious errors are the type of errors that stop the CPU operation.
Fatal errors are also the type of errors that stop the CPU operation. (Refer to Section 8.3.3.)
App - 9
Table 2 Link special relay (SB) list (Continued)
Description
Indicates the cyclic transmission status of the remote sub-master
station. (Including the status at an online loop test)
Off: Cyclic transmission normal
On: Cyclic transmission abnormal
Indicates the station type that is controlling cyclic transmission at
the remote I/O stations.
Off: Remote master station
On: Remote sub-master station
Indicates the parameter transmission status of each station. (Not
applicable to reserved stations and the station with the maximum
station number or higher)
Off: Executing communication other than parameter
communication
On: Executing parameter communication
Stations that are communicating parameters can be checked in
Parameter communication status of each station (SW0078 to
SW007B).
Depending on the timing of the link refresh, Parameter
communication status of each station (SW0078 to SW007B) and
the update may be offset by one sequence scan.
Indicates the low-speed cycle communication status.
It is indicated to have transmitted by turning the bit on for either
the SB007A or SB007B.
SB007A
SB007B
Cycle interval
Indicates the parameter status of each station. (Not applicable to
reserved stations and the station with the maximum station
number and higher)
Off: No station detected parameter errors
On: A station detected parameter errors
Stations that have parameter errors can be checked in
Parameter error status of each station (SW007C to SW007F).
Depending on the timing of the link refresh, Parameter error
status of each station (SW007C to SW007F) and the update may
be offset by one sequence scan.
Indicates the operation status of each station's CPU on the PLC-
to-PLC network (including the host station).
Off: All stations normal
On: A moderate or serous error identified
If a moderate or serious error is identified, the status of each
station can be checked in CPU operation status of each station
(1) (SW0080 to SW0083).
Depending on the timing of the link refresh, CPU operation status
of each station (1) (SW0080 to SW0083) and the update may be
offset by one sequence scan.
Indicates the operation status of each remote I/O station on the
remote I/O network (including the host station).
Off: All stations normal
On: Error station identified
If any error station is identified, the status of each station can be
checked in CPU operation status of each station (1) (SW0080 to
SW0083).
Depending on the timing of the link refresh, CPU operation status
of each station (1) (SW0080 to SW0083) and the update may be
offset by one sequence scan.
MELSEC-Q
Availability
Remote
Control
Normal
master
station
station
station
Optical Coaxial Optical Coaxial Optical Coaxial Optical Coaxial
Remote I/O
station
App - 9