Profinet controller/device
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

2 Hardware overview

2.1 Main computer

Connections
The I/O network can be connected to one of the the Ethernet ports WAN, LAN 2,
or LAN 3 on the main computer.
The following figure illustrates where the Ethernet port connectors, are placed on
the main computer.
xx1500000391
Connector
X2
X3
X4
X5
X6
Application manual - PROFINET Controller/Device
3HAC050969-001 Revision: G
Label
Service
LAN 1
LAN 2
LAN 3
WAN
Note
It is not supported to connect multiple ports of the main computer (X2 - X6) to
the same external switch, unless static VLAN isolation is applied on the external
switch.
© Copyright 2015-2018 ABB. All rights reserved.
Description
Port to the robot's private network. Intended to be left empty
so that service personnel can use it to connect to the com-
puter unit.
Port to the robot's private network. Normally used to connect
the FlexPendant.
Port to the robot's private network.
By default LAN 3 is configured for an isolated LAN3 network.
Can be reconfigured to be a part of the private network.
Wide Area Network that can host a public industrial network.