7. FEATURES RELATED TO MAINTENANCE AND FAILURE ANALYSIS
7.2 Logging the Trend of the Temperature inside the Chassis
7.2.1 Overview
This function periodically measures the temperature inside the chassis of this equipment and
records the data into a log file. You can adjust the logging interval for the temperature inside
the chassis by using the logging interval setup command. The default setting for the logging
interval is 60 minutes. You can select the setting from three options: 10, 30, and 60 minutes.
7.2.2 Log files
The temperature inside the chassis is recorded in a log file at the specified logging intervals.
When this equipment runs continuously for 8 hours or more, the highest and lowest
temperatures in 8 hours are also recorded every 8 hours. For either file, if the log gets full,
log entries are overwritten from the first entry.
Table 7-1 shows the name of each log file.
Parent folder
%ProgramFiles%\HFWRAS\log
<Checking log information>
You can check log information by opening the log files using an application such as
Notepad. The files are in the csv format. You can use spreadsheet or database software to
load the log information and draw graphs.
You can also use the log information collection window and the logsave command to
collect those log files. For information about how to use the logsave command, refer to
"7.5.1 Log information collection command (logsave)" in the "HF-BT1000
INSTRUCTION MANUAL (manual number BT-62-0002)".
Table 7-1 Log Files
File name
The temperature inside the chassis is recorded in
temp.csv
this file at the logging intervals.
(Maximum of 51200 entries)
The highest and lowest temperatures in 8 hours are
temp_mm.csv
recorded in this file.
(Maximum of 1100 entries)