4. CHECKING THE HARDWARE STATUS
4.5.4 Objects in the extended MIB for HF-BT
In order to acquire the hardware status of this equipment from a remote device, use the
extended MIB for HF-BT. Note that the extended MIB for HF-BT is the same MIB as the
extended MIB for HF-W offered for the HITACHI INDUSTRIAL COMPUTER HF-W
series. This subsection provides a list of objects defined in the extended MIB for HF-BT and
a description of those objects.
(1) Objects related to the hardware conditions and settings
Table 4-10 shows a list of the objects related to the hardware status and a description of
those objects. The object ID of each object is obtained by either replacing the following
"x" with the object in the following table or replacing the following "y" with the object
number in the table.
Object ID: .iso.org.dod.internet.private.enterprises.Hitachi.systemExMib.
hfwExMib.hfwRasStatus.x (x is an object in the table below)
or
.1.3.6.1.4.1.116.5.45.1.y (y is an object number in the table below)
No.
Object
1
hfwFan
2
hfwFan.fanNumber
3
hfwFan.fanTable.fanEntry.fanIndex
4
hfwFan.fanTable.fanEntry.fanName
5
hfwFan.fanTable.fanEntry.fanStatus
6
hfwTemp
7
hfwTemp.tempNumber
8
hfwTemp.tempTable.TempEntry.tempIndex
9
hfwTemp.tempTable.TempEntry.tempName
10
hfwTemp.tempTable.TempEntry.tempStatus
11
hfwHdd
12
hfwHdd.hddNumber
13
hfwHdd.hddTable.hddEntry.hddIndex
14
hfwHdd.hddTable.hddEntry.hddStatus
Table 4-10 Objects Related to the Hardware Status
Object
number
1
1.1
1.2.1.1
1.2.1.2
1.2.1.3
2
2.1
2.2.1.1
2.2.1.2
2.2.1.3
3
3.1
3.2.1.1
3.2.1.2
Description
Fan condition group
The number of monitored
fans
Index number of fanEntry
Fan name
Fan condition
Temperature condition
group
Number of monitored
temperatures
Index number of tempEntry
Name of the temperature to
bemonitored
Temperature condition
Drive condition
group
Number of monitored drive
bays
Index number of hddEntry
Drive condition
4-28
Description of the values
CS fan: Case fan
CPU fan: CPU fan
1: Normal
2: Error
Internal temperature:
Temperature inside the chassis
1: Normal
2: Error
1: Healthy
2: Not mounted
3: Failure anticipated
5: Used hours exceeded the
threshold
7: Offline
8: Rebuild
99: Unknown
(1/2)