GE AF-650 GP Programming Manual page 82

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Preset ref. bit
Preset ref. 0
Preset ref. 1
Preset ref. 2
Preset ref. 3
Preset ref. 4
Preset ref. 5
Preset ref. 6
Preset ref. 7
3.5.2 C-2# Jog Set-Up
Parameters to configure Jog Speed, Jog Accel/Decel Time and Quick Stop Decel Time.
C-20 Jog Speed [Hz]
Range:
0 Hz*
[0.0 - par. H-14 Hz]
C-21 Jog Speed [RPM]
Range:
150. RPM*
[0 - par. H-13 RPM]
C-22 Jog Accel/Decel Time
Range:
3.00 s*
[0.01 - 3600.00 s]
2
0
0
0
0
1
1
1
1
Function:
The jog speed is a fixed output speed at which the frequency converter is running when the jog function
is activated.
See also par. C-22 Jog Accel/Decel Time.
Function:
Enter a value for the jog speed n
, which is a fixed output speed. The frequency converter runs at this
JOG
speed when the jog function is activated. The maximum limit is defined in par. F-17 Motor Speed High
Limit [RPM].
See also par. C-22 Jog Accel/Decel Time.
Function:
Enter the jog ramp time, i.e. the acceleration/deceleration time between 0 RPM and the rated motor
frequency n
. Ensure that the resultant output current required for the given jog ramp time does not
s
exceed the current limit in par. F-43 Current Limit. The jog ramp time starts upon activation of a jog signal
via the control panel, a selected digital input, or the serial communication port.
AF-650 GP Programming Guide
1
0
0
0
0
1
1
0
1
1
0
0
0
1
1
0
1
1
3
81