NOTE
• Set consecutive numbers for the station numbers. (Do not skip a number in sequence like "station number 1 - station
number 2- station number 4".) The station number does not have to match with the physical connection sequence. (There is
no problem with having the physical connection sequence like "station number 1 - station number 3 - station number 4 -
station number 2".)
• One inverter occupies one station. (One remote device station)
• "L.ERR" LED flickers if the setting is changed. When power is switched on again or the RES signal is turned on, the setting
value is reflected and the LED turns off.
46