Device no.
Signal
Fault record
RWrC
(energization time)
Reply code
RWr10 to
RWr19
Read data
 Reply code definition
The reply to the instruction execution is set to RWr2, 10, 12, 14, 16, 18.
When executing the frequency setting (RYD, RYE) or instruction code execution (RYF), check the reply code (RWr2) in the
remote register after execution.
Data
H0000
Normal
H0001
Write mode error
Reply code
Parameter selection
H0002
error
H0003
Setting range error
70
DETAILS OF INPUT AND OUTPUT SIGNALS
Energization time of the fault record No. specified in RWw8 is stored.
When "1" is set in RYF, the reply codes corresponding to the instruction code RWw10, 12, 14, 16,
and 18 are set. The value "0" is set for a normal reply and other than "0" is set for data fault, mode
error, etc. (Refer to
page
70.)
For a normal reply, the reply data to the instruction specified by the instruction code is set.
Item
No error (normal completion of instruction code
execution)
Parameter write was attempted during operation
other than a stop in the network operation mode.
Unregistered code number was set.
Set data is outside the permissible data range.
Description
Alarm definition
Remarks
• Reply code to RWr2 when Pr.544
= 0
• Reply code to RWw10, 12, 14,
16, and 18 when Pr.544 = 18