Troubleshooting; Proceed As Follows - Bosch Rexroth 1MB Instructions Manual

Kit spindle motor
Hide thumbs Also See for Rexroth 1MB:
Table of Contents

Advertisement

DOK-MOTOR*-1MB********-IT01-EN-P
Rexroth 1MB Kit Spindle Motor
11

Troubleshooting

11.1

Proceed as Follows

Malfunction
The motor does not run
Vibrations
Running noise
High motor temperature
Motor temperature monitoring unit
responds
Wrong or incorrect temperature dis‐
played
Possible causes for the malfunctioning of 1MB motors can be limited to the
following areas:
Motor cooling circuit and temperature curve
Internal temperature sensor
Mechanical damage of the motor
Mechanical connection to machine
Encoder and temperature sensor are controlled by the controller or the con‐
trol unit; corresponding diagnostic messages are displayed. Observe the in‐
structions in the corresponding documentation.
The following sections describe some failure states with possible causes by
way of example. This list is not exhaustive.
Failure cause
Drive enable is missing
Controller fault
Supply voltage is missing
Brake is not released
Coupling elements or attachments are
poorly balanced
Adjustment of shaft end attachments
(coupling, gearbox, ...) is insufficient
Mounting screws are loose
Foreign bodies within the motor
Bearing is damaged
Operation outside of characteristic data
Heat dissipation is impaired
Temperature sensor not connected
Temperature sensor is defective
Fig.11-1:
Malfunctions on 1MB motors
In the case of malfunctions or troubleshooting, please observe the
notes in the project planning manual, too. If necessary, the manu‐
facturer must be contacted.
Bosch Rexroth AG
Troubleshooting
Measures
Activate the drive enable
Troubleshooting according to the docu‐
mentation of the controller
Check the supply voltage
Check the brake activation
Re-balance
Re-align the attachments
Lock the screw connections as specified
Stop operation of the motor -> repair by
manufacturer
Stop operation of the motor -> repair by
manufacturer
Reduce the load, check the sizing if nec‐
essary
Clean the motor
Check the coolant circuit of liquid cooling
systems
Connect the temperature sensor
Connect backup temperature sensor
51/61