GE DigitalFlow XGS868i Programming Manual page 119

Panametrics steam ultrasonic mass flow transmitter
Table of Contents

Advertisement

C.5.5d The Advanced Features Option
This option enables you to enable the more advanced features of the meter. In this option you can do the following:
enter a table of K-factors (based on velocity or reynolds number) that compensates for non-linear flow rates
enable mass flow (calculated for static fluid density)
The Multiple K Factors Option
Use this option to enter a table of K-factors. K-factors are used to create a curve for the flow range (based on velocity
or reynolds number) that compensates for non-linear flow rates. The meter accepts from 2 to 20 pairs. Complete the
following steps to enter multiple K factors for velocity or reynolds values:
1. From the Advanced Features option menu, highlight and double-click on Multiple K Factors in the center pane.
2. Double-click on Yes to Activate Multi K Factors or on No to disable this option.
NO
If
was selected, the meter returns to the Advanced Features window. If
3. Double-click on the desired Custom Type (velocity or reynolds).
If you selected CstR (Reynolds), enter the desired Kinematic Viscosity, and click [Next Item].
4. Double-click on Yes to Edit the K-factor Table or on No to retain the current K-factor table (and return to the
Advanced Features window).
Note: If the necessary velocity/reynolds vs. K-factor data was not provided with the Model XGS868i's documentation,
the K-factor table cannot be edited.
NO
If
was selected, the meter returns to the Advanced Features window. If
5. Enter the Number Of K-factors (from 2 to 20) to be entered into the table, and click [Next Item].
Note: When editing the K-factor table, the velocities must be entered in increasing order.
6. Enter the Velocity/Reynolds Value for K-factor number "X" and click [Next Item].
7. Enter the K-factor corresponding to velocity/reynolds number "X" (0.333 to 3.0) and click [Next Item].
The Velocity # and K Factor # prompts repeat for each pair. After entering all the pairs, the meter returns to the
Advanced Features window.
DigitalFlow™ XGS868i Programming Manual
Appendix C. Programming the XGS868i Using PanaView™
YES
was selected, proceed to Step 3.
YES
was selected, proceed to Step 5.