4. Insert the pre-assembled replacement module straight into the chassis, and gently
but firmly push the pack into position.
The battery pack is automatically connected.
5. Tighten the thumbscrew by turning it clockwise.
6. Replace the server bezel.
7. Dispose of the old battery pack in accordance with environmental regulations or
return to the supplier.
Collecting system backups and diagnostics
After replacing the battery, collect system backups and diagnostics.
Procedure
1. Connect to the back-end NAS Private Management Switch.
2. Open a browser session to the SMU. (External: 192.0.2.1; Embedded: 192.0.2.2).
3. Login as Username: admin Password: nasadmin
4. Back up the Server registry (Embedded SMU - this will include the SMU
configuration).
a. Navigate to Home > Server Settings > Configuration Backup and Restore.
b. Click Backup.
c. Save the registry file to a location on your computer.
d. Verify that the archive file can be opened and the contents can be extracted.
5. Backup the SMU Configuration - External SMU ONLY.
a. In the GUI, navigate to SMU Administration > SMU Backup and Restore
b. Click Backup SMU: Backup.
c. Save the configuration file to a location on your computer.
d. Verify that the archive file can be opened and the contents can be extracted.
6. Collect Diagnostics from the cluster.
a. Navigate to Home > Status and Monitoring > Download Diagnostics
b. Check only the check boxes and radio button shown below .
c. Click download.
Hitachi NAS Platform and Hitachi Unified Storage Series 4000 Hardware Reference
Chapter 5: Replacing server components
Collecting system backups and diagnostics
71