Configuring the replacement server
Before you begin
Obtain the necessary IP addresses to be used for the replacement server. Servers
shipped from the factory have not yet had the nas-preconfig script run on them, so a
replacement server will not have any IP addresses pre-configured for your use. You need
IP addresses for the following:
192.0.2.200/24 eth1 (cluster IP)
■
192.0.2.2/24 eth1 (testhost private IP)
■
192.168.4.120/24 eth0 (testhost external IP, which might vary)
■
When you run the nas-preconfig script, it reconfigures the server to the previous
settings. This step allows the SMU to recognize the server as the same and allows it to be
managed. Reconfigured settings:
IP addresses for Ethernet ports 0 and 1
■
Gateway
■
Domain name
■
Host name
■
On the replacement server:
Procedure
1. Log in to the server.
2. Run the nas-preconfig script.
3. Reboot if you are instructed to by the script.
4. Log in to the SMU using one of the IP addresses you obtained.
5. Use a KVM (keyboard, video, and mouse) or a serial cable to connect to the serial
port on the server.
Alternatively, you can connect by way of SSH using the following settings:
115,200 b/s
■
8 data bits
■
1 stop bit
■
No parity
■
No flow control
■
VT100 emulation
■
6. Log in as root (default password: nasadmin), and enter ssc localhost to access
the BALI level command prompt.
7. Enter evs list to obtain the IP configuration for the server.
8. Using a supported browser, launch the NAS Manager using either of the IP
addresses acquired from the EVS list output.
9. Click Yes, and log in as admin (default password: nasadmin).
10. Verify and, if necessary, convert the new server to the model profile required.
Hitachi NAS Platform and Hitachi Unified Storage Series 4000 Hardware Reference
Appendix A: Server replacement procedures
Configuring the replacement server
96