1.4
EEPROM Parameter Initialization (Maintenance mode 01)
Refer to
Chapter 5 "1.3.1 EEPROM Parameter Initialization (Maintenance mode 01, 91)"
on the execution.
1.5
Restore Head Calibration Data (Maintenance mode 68)
Refer to Restore on
Head Calibration Data (Maintenance mode 68)"
up.
If restore is successful, the operation in Section 1.15 is not necessary.
1.6
Set the Serial Number (Maintenance mode 80)
Set the serial number, referring to
mode
80)".
The serial number can also be set with the service setting tool (BrUsbSn.exe).
The serial number setting procedure is given below.
(1) Turn the machine on and switch it to the maintenance mode.
(2) Connect the machine to your PC using a USB cable.
(3) On the PC, run the service setting tool (BrUsbSn.exe) to display the following window.
(4) In Product Category, select [1. Ink-Model].
(5) Select [2013 Model_1].
Chapter 5 "1.3.25 Updating of Head Property Data and Backup/Restoration of
Chapter 5 "1.3.32 Display of the Equipment's Log (Maintenance
to restore the head calibration data that was backed
4-4
for details