Power Electronics:
Control version / of heat emitters
Number of outputs / for heating power
Number of heat emitters / per output / maximum
Output voltage / at output / for heating power
Power capacity / per output
Output current / at output / for heating power /
Rated value
Peak current
Design of short-circuit protection / for heating
power / per output
Melting I2t value
Design of the overvoltage protection
Galvanic isolation / between the outputs
Type of electrical connection / at output / for
heating and fan
Type of connectable conductor cross-section
/ for heating and fan / solid
Type of connectable conductor cross-section
/ for heating and fan / finely stranded / with
core end processing
Type of connectable conductor cross-
sections / at AWG conductors / stranded
Product function / voltage detection
Communication:
Design of the interface
Display:
Number of status displays
Display version / as status display by LED
Auxiliary circuit:
Design of the power supply
Active power consumption / maximum
Protective and monitoring functions:
Product function / Temperature monitoring
Type of the temperature monitoring
Diagnostics function
Tripped fuse
Cable break
Heat emitter failure
SIPLUS HCS4300
Operating Instructions, 11/2015, A5E35452705A/002
Half-wave control and soft start
9
1
400 V
200 W ... 7 680 W
16 A
150 A
Fuse 16 A
250 A²·s
Transil Diode
No
Connector, 3-pin with tension spring connection
1x (0.2 ... 10 mm²)
1x (0,25 ... 6 mm²)
1x (24 ... 8)
Yes
system interface
12
LED green = ready, LED yellow = heating on/off, LED red = error
display, LED red = error for each channel
Power supply via CIM
8 W
Yes
NTC thermistor
Voltage diagnostics
Yes
Yes
Yes
13.1 Technical specifications for POM
200 W ... 7 200 W
15 A
135 A
Fuse 15 A
225 A²·s
Technical data
125

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcs4300

Table of Contents