Siemens 6SN1123-1AA00-0DA2 Configuration Manual page 104

Simodrive 611 series drive converter
Table of Contents

Advertisement

02.07
05.01
S
Table 4-13
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Note:
The inputs on the control must not be assigned any signals other than the intended sig-
nals. Otherwise, sporadic or permanent malfunctions can occur.
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
4.2 "SIMODRIVE 611 universal HRS" control board
Resolvers
Encoder signal input of motor encoder X411, X412 (resolver)
Pin
X411 (axis 1)
X412 (axis 2)
Reserved, do not use
M
Ground
AP
Resolver, sinusoidal
AN
Resolver, sinusoidal, inverted
M
Inner shield ground
BP
Resolver, cosine
BN
Resolver, cosines, inverted
M
Inner shield ground
EXC_POS
Resolver excitation (pos.)
Reserved for test purposes, do not use
EXC_NEG
Resolver excitation (neg.)
Reserved for test purposes, do not use
THMOTP
KTY 84 (+) temperature sensor
Reserved, do not use
Reserved for test purposes, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
M
Inner shield ground
THMOTCOM
KTY 84 (–) temperature sensor
4 Control Units
Function
4-103
4