02.07
05.01
S
Table 4-13
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Note:
The inputs on the control must not be assigned any signals other than the intended sig-
nals. Otherwise, sporadic or permanent malfunctions can occur.
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
4.2 "SIMODRIVE 611 universal HRS" control board
Resolvers
Encoder signal input of motor encoder X411, X412 (resolver)
Pin
X411 (axis 1)
X412 (axis 2)
–
Reserved, do not use
M
Ground
AP
Resolver, sinusoidal
AN
Resolver, sinusoidal, inverted
M
Inner shield ground
BP
Resolver, cosine
BN
Resolver, cosines, inverted
M
Inner shield ground
EXC_POS
Resolver excitation (pos.)
–
Reserved for test purposes, do not use
EXC_NEG
Resolver excitation (neg.)
–
Reserved for test purposes, do not use
THMOTP
KTY 84 (+) temperature sensor
–
Reserved, do not use
–
Reserved for test purposes, do not use
–
Reserved, do not use
–
Reserved, do not use
–
Reserved, do not use
–
Reserved, do not use
–
Reserved, do not use
–
Reserved, do not use
–
Reserved, do not use
–
Reserved, do not use
M
Inner shield ground
THMOTCOM
KTY 84 (–) temperature sensor
4 Control Units
Function
4-103