Siemens 6SN1123-1AA00-0DA2 Configuration Manual page 109

Simodrive 611 series drive converter
Table of Contents

Advertisement

4 Control Units
4.3 "HLA module" control board
Pressure sensor
system
4-108
Connection for two pressure sensors per axis
S
X111:
Axis 1 (sensors 1A, 1B)
S
X112:
Axis 2 (sensors 2A, 2B)
Table 4-15
Connectors X111, X112; each 15–pin sub–D socket connector
Pin
X111
X112
1
P24DS
P24DS
2
P24DS
P24DS
3
4
5
M24EXT
M24EXT
6
7
8
9
M24EXT
M24EXT
10
M24EXT
M24EXT
11
PIST1BN
PIST2BN
12
PIST1BP
PIST2BP
13
M24EXT
M24EXT
14
PIST1AN
PIST2AN
15
PIST1AP
PIST2AP
1)
I = Input, O = Output
The inputs are differential with 40 kΩ input resistance.
The input voltage range is 0...+10 V.
The supply output has an electronic short–circuit protection function.
The supply output is dimensioned for a total current (4 sensors) of 200 mA.
Supply for pressure sensors with 26.5 V "2% according to the external infeed
at X431.
Notice
The external 26.5 V supply voltage cannot be replaced by a 24 V supply
voltage.
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Type
Function
1)
O
External +24 V supply for the
pressure sensor
O
External +24 V supply for the
pressure sensor
Not assigned
Not assigned
O
External 0 V supply for the
pressure sensor
Not assigned
Not assigned
Not assigned
O
External 0 V supply for the
pressure sensor
O
Extra pin for jumper between pins 10–11 with
3–wire connection
I
Analog actual value signal, reference ground
I
Analog actual value signal, max. range 0...10 V
O
Extra pin for jumper between pins 13–14 with
3–wire connection
I
Analog actual value signal, reference ground
I
Analog actual value signal, max. range 0...10 V
© Siemens AG 2012 All Rights Reserved
05.01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents