Siemens 6SN1123-1AA00-0DA2 Configuration Manual page 228

Simodrive 611 series drive converter
Table of Contents

Advertisement

02.03
05.01
Note
If the objective is that an application is not to have a leading contact over the
complete power range of the infeed modules, then this can be implemented
using the following measures:
S
S
The I/R modules then operate as UI modules and can be operated with
additional loads connected to a switching element without leading contact.
Leading contact is
For the configurations that are now described, a leading contact for the switch-
absolutely
ing element is absolutely necessary:
necessary
S
S
The following diagram shows two examples where a leading contact is abso-
lutely necessary.
Switching element with
leading contact
I/RF module
I/RF module
Fig. 7-10
Examples of a configuration where a leading contact is required
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
7.3 Overcurrent protective devices, transformers and main switch
Changing over from any present I/R modules to unregulated infeed (this is
generally the case for 480 V applications).
Deactivating the regenerative feedback if I/R modules are being used.
If one or more I/R modules are connected, together with other loads, through
a switching element.
If NE modules having different power classes are connected together to one
switching element. In this case, the restrictions, described on the following
page, must be carefully fulfilled.
Further
I/RF module
consumers
16 kW
7 Line Supply Connection
Switching element with
leading contact
I/RF module
UI module
120 kW
10 kW
7
7-227