Chapter 3 Appendix
(3) The list on the messages related to POST
Error
Class
code
UEFI
101
UEFI
104
UEFI
121
UEFI
218
UEFI
224
UEFI
225
UEFI
226
UEFI
227
UEFI
244
UEFI
251
UEFI
253
UEFI
254
Error message
Option ROM Error. An option ROM for a
PCIe device is invalid.
ASR Timer Failure
A Critical Error occurred prior to this
power-up.
DIMM Initialization Error - All DIMMs are
mapped out due to memory errors except
for one to allow the system to boot.
Additional errors may be present on the
remaining DIMM. System is booting in a
degraded state.
Power Fault Detected - FlexLOM %1
Power Fault Detected-Mezzanine %1.
Power Fault Detected - Embedded Storage
Controller %1.
Power Fault Detected - M.2 riser
IMPORTANT: The device in PCIe Slot %1
is SRIOV capable but is installed in a slot
that does NOT support SRIOV.
IMPORTANT: Switches SW1 and SW3 are
ON. This is only used to recover %1
functionality.
IMPORTANT: One or more embedded
PCIe Device(s) are attached to a
non-installed processor and will not
function.
IMPORTANT: The PCIe Device installed in
Slot %1 has no corresponding processor
installed and will not function.
Express5800/R120h-1E, R120h-2E Maintenance Guide
Action
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
Turn off the power on the unit, disconnect the power
cord, and check the installation of FlexLOM %1. Wait 30
seconds, and then restart it. If the problem persists,
contact your sales representative.
Turn off the power on the unit, disconnect the power
cord, and check the installation of mezzanine %1. Wait
30 seconds, and then restart it. If the problem persists,
contact your sales representative.
Turn off the power on the unit, disconnect the power
cord, and check the installation of internal storage
controller %1. Wait 30 seconds, and then restart it. If the
problem persists, contact your sales representative.
Turn off the power on the unit, disconnect the power
cord, and check the installation of M.2 riser. Wait 30
seconds, and then restart it. If the problem persists,
contact your sales representative.
When using the SRIOV, install an optional card in the
slot where the SRIOV is supported. If the problem
persists, contact your sales representative.
Set the maintenance switch to OFF unless the setting is
specified in the operating procedure etc.
When operating the maintenance switch, follow the
procedure in Chapter 1 (7. Resetting and Clearing the
Server) in this manual.
If the problem persists, contact your sales
representative.
Some built-in devices are not available unless the
processor is added. Add a processor if necessary. If the
problem persists, contact your sales representative.
The optional card is connected to a PCIe slot that is not
available unless a processor is added. Change the slot
which the PCIe expansion card is connected to,
otherwise add a processor. If the problem persists,
contact your sales representative.
1. IML Error Message