Chapter 3 Appendix
Error
Class
code
UEFI
334
UEFI
335
UEFI
336
UEFI
337
UEFI
338
UEFI
340
UEFI
341
UEFI
342
Error message
%1 RESTful API Error - RESTful API GET
request failed (HTTP Status Code = %2).
BIOS configuration resources were not
consumed.
%1 RESTful API Error - RESTful API PUT
request failed (HTTP Status Code = %2).
BIOS configuration resources may not be
up-to-date.
%1 RESTful API Error - One or more
configuration settings could not be applied.
%1 RESTful API Error - Unable to
communicate with %2 FW due to
Datacenter Configuration Lock being
enabled. BIOS configuration resources
may not be up-to-date.
%1 RESTful API Error - Unable to
communicate with iLO FW. BIOS
configuration resources may not be
up-to-date.
NVDIMM Error - Backup Error -
Processor %1, DIMM %2
(SN:%3-%4-%5-%6). Persistent data
backup failed and data is irrecoverably lost.
NVDIMM Error - Restore Error -
Processor %1, DIMM %2
(SN:%3-%4-%5-%6). Persistent data
restore failed and data is not available.
Data is not lost unless the issue persists.
NVDIMM Error - Uncorrectable Memory
Error - Processor %1, DIMM %2
(SN:%3-%4-%5-%6). This NVDIMM will
not be available to the operating system
and data may have been lost.
Express5800/R120h-1E, R120h-2E Maintenance Guide
Action
Please take actions in the following order.
1. Turn off the unit, disconnect the power cord, wait 30
seconds, and then restart it.
2. If the problem persists, reset the iLO following the
procedure in Chapter 1 (7. Resetting and Clearing the
Server) in this manual.
3. If the problem persists, updating the iLO
firmware/system ROM may solve the problem. Update
the iLO firmware/system ROM.
4. If the problem persists, contact your sales
representative.
Please take actions in the following order.
1. Turn off the unit, disconnect the power cord, wait 30
seconds, and then restart it.
2. If the problem persists, reset the iLO following the
procedure in Chapter 1 (7. Resetting and Clearing the
Server) in this manual.
3. If the problem persists, updating the iLO
firmware/system ROM may solve the problem. Update
the iLO firmware/system ROM.
4. If the problem persists, contact your sales
representative.
Refer to the SettingsResult property of RESTful API to
check the setting contents.
If the problem persists, contact your sales
representative.
Disable data center configuration lock.
If the problem persists, contact your sales
representative.
Restore the factory default settings using the Restore
Default Manufacturing Settings option via System
Configuration > BIOS/Platform Configuration
(RBSU) > System Default Options in the system utility.
If the problem persists, contact your sales
representative.
Contact your sales representative.
Contact your sales representative.
Contact your sales representative.
1. IML Error Message
189