11. SAFETY SYSTEM

WARNING!
Observe If overheating occurs, a buzzer will sound
and the following text will appear in the display
ELEMENT
OVERHEATED
The heat will shut off in the event of a fault to the ele-
ment sensor.
Switch off the pan by:
Pressing On/Off
overheating protection. The display goes out.
Wait 5 seconds!
Press On/Off
. Display lights.
If the warning is still lit
Check the water level in the pressure vessel.
(See Filling pressure vessel with water in the in-
stallation instructions.)
If the warning is still lit, call in a qualified
technician.
The water level in the vessel should be checked at
least once/quarter. (See Filling pressure vessel with
water in the installation instructions.)
NOTE! Boiling pans with the level control option
regulates the water level in the vessel automatic-
ally. There is no need to check the water level in the
vessel.

11.1 Safety valve

Fig.1
A.
Safety valve
B.

Manometer

C.
Steam trap
D.
Meter tap (for accredited
authority at final inspection)
A properly functioning safety valve is an extremely
important part of the pan's safety system.
Safety valve (Fig. 1 pos. A) opens automatically if
the pressure exceeds 1.5 bar.
Switch off the pan immediately and call in a
qualified technician.
Warning!
If the safety valve (Fig. 1 pos. A) opens, hot steam
will blow out from the valve.
Regular checks of the safety valve should be
performed by trained personnel.
We recommend: once a week.
EN | 02-2015
OVERHEATING
(see Fig. 3) for resetting the
DOC.N
OPERATING INSTRUCTIONS | SMART LINE | BOILING PAN
11.2 Checking of safety valve
Fig 2
A:1
Lift the handle to allow the steam free passage
through the safety valve, Fig.2 pos. A:1 and
Fig.2 pos. A:2.
If you cannot get the valve to open (blow)it must
be replaced immediately. Call in a qualified techni-
cian.
11.3 Manometer
Manometer Fig. 1 pos.B, measures the steam pres-
sure. May not exceed 1.5 bars.
If the display goes into the red field
Switch off the pan immediately and call in a
qualified technician.
*
For the correct display of the pressure, the
green cap on the manometer can be lifted.
NOTE: The green cap must be pressed in when
the pan is tilted.
11.4 Steam trap
Steam trap Fig. 1 pos.C, releases the cold air into
the steam generator when starting the pan. When
the water in the steam generator starts to boil and
hot steam starts to flow out, the steam trap closes
automatically.