Download Print this page

Sanyo VM-EX70P Adjustment Manual page 74

8 mm camcorder

Advertisement

3. Zooming Curve Adjustment
[Connection]
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ
[Adjustment]
Measuring Point
Measuring Equipment
J9001 @)
Digital voltmeter
@)
[ADJ. END]
J9001
[GND]
Siemens star (from lens surface: 1 1 0 -
1 50 cm, illuminance: 50 to 1 20 lux)
ADJ. Location
CD
Preparation:
Short pin
and pin ®
J9001 .
Adjusting method:
1 . Turn on the power by changing the Stand-by switch from
"POWER SAVE" to "STANDBY".
2. The DC voltage of J9001 @) will change from High (4 - 5
V) to Low (below 1 V), and the adjustment will be
completed. (About 1 5 seconds)
NOTES:
When the power is turned on, the focus adjusts on the
subject (Siemens star). After the focus has been adjusted ,
the screen will blackout for a few seconds. When the
screen picture returns, the adjustment is completed.
Focus Position Adjustment should be completed before­
hand.
E
f
VSUB
abbreviation
9.0
9.5 1 0.0 1 0.5 1 1 .0 1 1 .5 1 2.0 1 2.5 1 3.0
Voltage [VJ
Condition
Power
OFF -+ ON
Subject
ADJ. Value
then short pin ® and pin
,
G
h
J
K
L
4. CCD Driving Voltage Adjustment
[Connection]
[Adjustment]
®
Measuring Point
J9001
[VSUB]
J9001 ®
@)
[PGL]
[GND] No designation
J9001
ADJ. Location
EVR CH1 [VSUB]
EVR CH2 [PG L]
@)
CD
Preparation:
of
Short pin
J9001 .
Adjusting method:
1 . Read the abbreviation of two digits displayed on the rear
side of CCD. The first digit displays PG L and the second
digit displays VSUB. Convert these to the voltage with the
table below.
For example, [4R] displays PGL
2. Operate the CH - UP key or the C H-DOWN key to
designated EVR CH1 .
3. Operate the DATA-CENT key, DATA - U P key and DATA­
DOWN key so that the voltage at [VSUB] becomes the
displayed voltage value
4. Press the WRT key to store the adjusting data.
5. Repeat steps 2. - 4., and use the WRT key to adjust in
the same manner the EVR CH2 [PGL] displayed voltage
±
value
0.1 V.
PGL
abbreviation
N
p
R
Q
Voltage [VJ
m
1 3.5 1 4.0 1 4.5 1 5.0 1 5.5 1 6.0 1 6.5 1 7.0 1 7.5 1 8.0 1 8.5
- 5-5 -
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ
Measuring Equipment
Digital voltmeter
Subject
ADJ. Value
Abbreviation voltage value
±
v
0.1
and pin ® , then short pin ® and pin
2.5 V, VSUB
=
±
0.1 V.
1
2
3
4
s
T
v
w
u
1 .0
2.0
2.5
1 .5
Condition
CAMERA EE
@)
of
1 4.5 V
=
5
6
7
x
y
z
3.5
4.0
3.0

Advertisement

loading

This manual is also suitable for:

126 032 05126 032 06126 032 00