1 1 . 5,1 00K AWB Adjustment
[Connection]
TP1 41
CJ CJ CJ
CJ CJ CJ
CJ CJ CJ
CJ
[Adjustment]
Measuring Point
Measuring Equipment
Vectorscope
TP141 [CP 1 )
Color viewer 5, 1 OOK
(video output)
TP1 43 (GND)
All white pattern
ADJ. Location
EVR CH1 1 , CH 1 2
@
Preparation:
Short pin
and pin ® of J9001 .
Adjusting method:
1 . Set the gain so that the burst comes to the end of the
vectorscope.
2. Press the RESET key once.
3. Press the READ key once while pressing the AI D key and
read out all the EVR data.
4. Adjust two EVRs of CH1 1 and CH 1 2 mutually so that the
luminance point displayed the white vector is positioned
on the center point as shown in the figure. (See page
5-1 O)
5. Press the WRT key once while pressing the AID key to
store the adjusting data.
O TP143
0
Condition
CAMERA EE
Subject
ADJ. Value
1 2. 2,800K AWB Adjustment
[Connection]
[Adjustment]
Measuring Point
TP1 41 [CP 1 )
(video output)
TP1 43 (GN D)
ADJ. Location
VR931 (R. G)
VR932 (8. G)
@ ,
Preparation:
Short pin
Adjusting method :
1 . Set the gain so that the burst comes to the end of the
vectorscope.
2. Adjust with the VR931 (R. G) and VR932 (8. G) so that
the luminance point displayed the white vector is
positioned on the center point as shown in the figure.
(See page 5 -1 0)
- 5-9 -
O TP1 43
TP1 41
0
Measuring Equipment
Vectorscope
Color viewer 5, 1 OOK
Subject
All white pattern
(Place L8A8s in front of the lens)
ADJ. Value
pin ® and pin ® of J9001 .
Condition
CAM ERA EE

Advertisement

loading

This manual is also suitable for: