Motorola MSF 5000 Instruction Manual page 260

Hide thumbs Also See for MSF 5000:
Table of Contents

Advertisement

Appendix
D Performance Specifications
MSF
5000
Instruction Manual
VHF
(132
-
174 MHz)
VHF
(132
-
174 MHz)
VHF
General
Description
\Nalue
or
Range
Number of Channels
4
standard up
to 15
frequencies optional on conventional
stations.
1
standard on trunked stations.
Input Voltage
(AC)
96
-132
Vac
@ 60
Hz
Optional
50
Hz,
110/220
Vac
Operating Temperature
-30°
C
to +60°
C
Dimensions
(HxWxD):
6
Watts
26.75" x 22" x 10" (68.0 x
56.0
x
25.4
cm)
25
Watts
26.75" x 22" x 10" (68.0 x 56.0 x 25.4
cm)
75
Watts
26.75" x 22" x 10" (68.0 x
56.0
x
25.4
cm)
125
Watts
26.75" x 22" x 10" (68.0 x 56.0 x 25.4
cm)
350
Watts
t
46" x 22" x 10"
(117.0
x
56.0
x
25.4
cm)
Weight:
6
Watts
130 Ibs.
(59
kg)
25
Watts
140 Ibs.
(64
kg)
75
Watts
140 Ibs.
(64
kg)
125
Watts
160 Ibs. (73
kg)
350
Watts
+
300 Ibs. (136
kg)
Input Power:
Standby
Transmit
(varies
w/options)
¢
6
Watts
60
Watts
80
Watts
25
Watts
60
Watts
80
Watts
75
Watts
80
Watts
300
Watts
125
Watts
80
Watts
425
Watts
350
Watts
150
Watts
1150
Watts
Metering
Optional interactive
DMP
provides
5
Watts audio, analog
metering and status display of control signals.
Optional interactive
RMP
provides
5
Watts audio and analog
metering.
+
Measurement does not include tip
feet.
t
The
75, 125,
and 350
Watt
VHF
stations
utilize dual voltage
(14
and
28
Vdc) power
supplies.
68P81092E12
3/19/94
D-2
Appendix
D Performance Specifications
MSF
5000
Instruction Manual
VHF
(132
-
174 MHz)
VHF
(132
-
174 MHz)
VHF
General
Description
\Nalue
or
Range
Number of Channels
4
standard up
to 15
frequencies optional on conventional
stations.
1
standard on trunked stations.
Input Voltage
(AC)
96
-132
Vac
@ 60
Hz
Optional
50
Hz,
110/220
Vac
Operating Temperature
-30°
C
to +60°
C
Dimensions
(HxWxD):
6
Watts
26.75" x 22" x 10" (68.0 x
56.0
x
25.4
cm)
25
Watts
26.75" x 22" x 10" (68.0 x 56.0 x 25.4
cm)
75
Watts
26.75" x 22" x 10" (68.0 x
56.0
x
25.4
cm)
125
Watts
26.75" x 22" x 10" (68.0 x 56.0 x 25.4
cm)
350
Watts
t
46" x 22" x 10"
(117.0
x
56.0
x
25.4
cm)
Weight:
6
Watts
130 Ibs.
(59
kg)
25
Watts
140 Ibs.
(64
kg)
75
Watts
140 Ibs.
(64
kg)
125
Watts
160 Ibs. (73
kg)
350
Watts
+
300 Ibs. (136
kg)
Input Power:
Standby
Transmit
(varies
w/options)
¢
6
Watts
60
Watts
80
Watts
25
Watts
60
Watts
80
Watts
75
Watts
80
Watts
300
Watts
125
Watts
80
Watts
425
Watts
350
Watts
150
Watts
1150
Watts
Metering
Optional interactive
DMP
provides
5
Watts audio, analog
metering and status display of control signals.
Optional interactive
RMP
provides
5
Watts audio and analog
metering.
+
Measurement does not include tip
feet.
t
The
75, 125,
and 350
Watt
VHF
stations
utilize dual voltage
(14
and
28
Vdc) power
supplies.
68P81092E12
3/19/94
D-2