Item
SUBNET
Sets the subnet mask of the unit.
The values that can be set for each octet are as follows.
1st octet: 0 to 255
2nd octet: 0 to 255
3rd octet: 0 to 255
4th octet: 0 to 255
In addition, the setting values will be checked when confirmed (written to flash memory), and an error mes-
sage will appear and setting will not be possible when the subnet mask is as follows.
0.0.0.0 and 127.0.0.1 cannot be set.
DEFAULT GATEWAY
Sets the default gateway of the unit.
The setting ranges are as follows.
(Factory default: 192.168.0.1)
1st octet: 1 to 223
2nd octet: 0 to 255
3rd octet: 0 to 255
4th octet: 1 to 254
However, the following addresses cannot be set.
Check the setting values during configuration.
Class D address (224.0.0.0 to 239.255.255.255)
Class E address (240.0.0.0 to 255.255.255.255)
MAC ADDRESS
Display the unit's MAC address. (Display only)
SAVE
Press the [MENU] dial to set the following items.
NETWORK SETTING
IP
PORT
SUBNET
DEFAULT GATEWAY
When settings are changed, they will not be applied if you do not perform a save. Furthermore, the unit will
operate according to the set information once restarted.
NOTE
Performing [SAVE] after changing the settings will store the setting value changes to the internal memory. Perform [SAVE] on
each screen. The setting values stored to memory will be applied after the unit is restarted.
Setting details