Programmable Monitoring - Toshiba G3 Workbook

Applications workbook
Table of Contents

Advertisement

The G3 has an extensive monitoring system which is employed via the keypad. The information
given in the monitor displays is useful while troubleshooting or commissioning applications.
Key
Display
MOTOR RUN DIRECTION:
FORWARD
MONITOR #1
MONITOR #2
MONITOR #3
MONITOR #4
STATUS: R:-- S1:-- S2:--
S3:-- S4:-- S5:--
ST:ON F:-- RES:--
S6:-- S7:-- S8:--
RCH:-- LOW:-- FLT:--
OUT:-- FAN:-- MC:ON
CUMULATIVE RUN TIME
PAST TRIP #1
NO ERROR
PAST TRIP #2
NO ERROR
PAST TRIP #3
NO ERROR
PAST TRIP #4
NO ERROR
MOTOR RUN DIRECTION:
FORWARD
For additional assistance, please contact Toshiba Adjustable Speed Drive Marketing Dept. at (800) 872-

Programmable Monitoring

Description
Indicates direction associated with speed reference. Keypad direction reference
is separate from terminal strip direction reference.
As these input terminals are shorted to CC, the "--" will change to "ON". Use
this as a troubleshooting tool.
As these input terminals are shorted to CC, the "--" will change to "ON". Use
this as a troubleshooting tool. S6, S7, and S8 exist only on option card.
As these output terminals close, the "--" will change to "ON". Use this as a
troubleshooting tool. OUT exists only on option card. MC always says "ON".
"FAN" shows "ON" when the drive's muffin fan is on.
.01 represents one hour. The timer is not resettable. An output contact can be
0.00
programmed to change state based on the CRT.
The drive stores past faults; to clear these, put a "4" into Standard Setting Mode
Selection in the UTILITY PARAMETERS group.
End/beginning of MONITOR mode