The G3 can be configured in a master/follower scenario in many different ways. For information
concerning the G3's RS485 master/follower function, see Application Guideline 9. The G3 has a high
frequency pulsed output as standard that can be used in conjunction with a Extended Terminal Block
Option Board (part number INV3-COM-D), to provide master/follower control. The pulse scenario
therefore requires one less option board than its RS485 counterpart. The INV3-COM-B can also be used
(see price book for more information on G3 option boards).
Connections
Master
G3
FP
On the followers, connect the ribbon cable from the INV3-COM-D board to the drive's CN6X connector. The CN6X connector is to
the left of the terminal strip.
Programming for the Master
Group
UTILITY PARAMETERS
UTILITY PARAMETERS
TERMINAL SELECTION PARAMETERS
Programming for the Follower(s)
Group
UTILITY PARAMETERS
UTILITY PARAMETERS
UTILITY PARAMETERS
FEEDBACK CONTROL PARAMETERS
FEEDBACK CONTROL PARAMETERS
FREQUENCY SETTING PARAMETERS
For additional assistance, please contact Toshiba Adjustable Speed Drive Marketing Dept. at (800) 872-

Master/Follower: Pulse Output

INV3-COM-D
PGB
CC
Follower
G3
CC
Parameter
Blind Function Selection
Feedback Control Parameters
"FP" Output Terminal Pulse Frequency
Parameter
Blind Function Selection
Feedback Control Parameters
Frequency Setting Parameters
PG Input: Number of Phases
Number of Pulses
Frequency Priority Selection #1
2192
Follower
G3
INV3-COM-D
PGB
CC
to other followers
Value
1
1
2
Value
1
1
1
1
360
4
23
56