2.3.3.4
DRIVE-CLiQ interface X500
Table 2-8
DRIVE-CLiQ interface X500
PIN
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interface: Tyco, order no.: 969556-5
2.3.3.5
Terminal Block X609
Table 2-9
Terminal block X609
Terminal Designation
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Max. connectable cross-section 1.5mm
* Series connection: NO contact, pre-charging contactor and bypass contactor
CAUTION
Active Interface Modules of frame size JI and HI require a signal on terminal X609:11 and 12
to control the fans. If this signal is not present during operation, the fans do not rotate and
the module is shut down on overtemperature.
Chassis Power Units Liquid Cooled
SINAMICS S120 Equipment Manual, Edition 12/2007, 6SL3097-2AM00-0BP4
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24V)
GND (0V)
P24
P24
M
M
L
L
N
N
Pre-charging contactor –A1*
Pre-charging contactor –A2*
Bypass contactor –A1*
Bypass contactor –A2*
Contactor feedback 1*
Contactor feedback 2*
2
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
24V power supply
Electronic ground
Technical specifications
Voltage: 24VDC (20.4V – 28.5V)
Power consumption: 0.25A max.
Voltage: 230VAC (195.5V – 264.5V)
Power consumption: 10A max.
Fan operating currents, see Table 2-11 and Table 2-12
Voltage: 230VAC
(195.5V – 264.5V)
Power consumption: 4A max.
Voltage: 230VAC
(195.5V – 264.5V)
Power consumption: 6A max.
Voltage: 230VAC (195.5V – 264.5V)
Max. permissible current: 6A
Line-Side Power Components
2.3 Active Interface Modules
To Active Line Module, X9:5
To Active Line Module, X9:6
To Active Line Module, X9:3
To Active Line Module, X9:4
2-15