Checking The Hydraulic-Fluid Level - Toro e-Dingo 500 Operator's Manual

Compact tool carrier
Hide thumbs Also See for e-Dingo 500:
Table of Contents

Advertisement

Checking the
Hydraulic-Fluid Level
Service Interval: Every 25 hours
Check the hydraulic-fluid level before the machine is
first started and after every 25 operating hours.
Refer to
Hydraulic Fluid Specifications (page
Important:
Always use the correct hydraulic
fluid. Unspecified fluids will damage the hydraulic
system.
1.
Park the machine on a level surface, remove
any attachment, raise the loader arms, and
install the cylinder locks.
2.
Shut off the machine, remove the key, and allow
the machine to cool.
3.
Remove the hood and lower front cover.
4.
Remove the fan shroud.
Figure 38
1. Bolt—3/8 x 1 inch (2)
5.
Clean the area around the filler neck of the
hydraulic tank.
34).
g390548
2. Fan shroud
6.
Remove the filler-neck cap and check the fluid
level on the dipstick.
The fluid level should be between the marks on
the dipstick.
1. Filler neck cap
7.
If the level is low, add enough fluid to raise it to
the proper level.
8.
Install the filler-neck cap.
9.
Install the fan shroud.
10.
Install the lower front cover and hood.
11.
Remove and store the cylinder locks and lower
the loader arms.
35
Figure 39
Figure 40
2. Dipstick
g390547
g421601

Advertisement

Table of Contents
loading

This manual is also suitable for:

2221922219g

Table of Contents