LUNA2000-2.0MWH-1H0, 2H0 Smart String ESS
User Manual
Figure 2-42 Position of the fire extinguishing board
(1) Position of the fire extinguishing board
Table 2-34 Technical specifications of the fire extinguishing board
Technical Specifications
Model
Operating voltage
Operating current
Operating temperature
Humidity
Dimensions (H x W x D)
2.8.4.7 Heat Detector
Figure 2-43 Appearance of the heat detector
Issue 02 (2021-11-15)
Copyright © Huawei Technologies Co., Ltd.
Fire Extinguishing Board
ENF1DETAA
24 V
≤ 1 A
- 30°C to +55°C
≤ 95% RH (non-condensing)
95 mm x 55 mm x 24 mm
2 Overview
56