Common Preparations (Preparing a USB Flash Drive)

Whether upgrading using the Updater functionality or download mode, you must store firmware following the rules below if
upgrading it using a USB flash drive.
NOTE:
Have firmware ready that can be used for USB upgrading in advance.
■ Register the system software (PC to USB)
Folder structure rules for USB flash drive
• Place the folder with firmware registration series name directly under the root folder.
• Directly under that folder (with firmware registration series name), place the unzipped firmware folders.
NOTE:
The firmware registration series name can be confirmed in the following service mode.
COPIER > DISPLAY > USER > SER-NAME
Firmware of up to 9 versions can be displayed.
Display firmware registration
Display firmware registration
Conceptual diagram
Example of folder structure