Advertisement

Ite
m
5
6
5. If cables are not labeled, label them before removing them from the server.
6. Remove all cables from the server, and remove the server from the rack.
7. Remove the rail mounts from the old server, and install them on the new server.
8. Remove the battery from the old server, and install it in the new server.
9. Remove the bezel from the old server, and install it on the new server.
10. Insert the new server into the rack, and connect the power cords to the power
supplies.

Configuring the replacement server

Before you begin
Obtain the necessary IP addresses to be used for the replacement server. Servers
shipped from the factory have not yet had the nas-preconfig script run on them, so a
replacement server will not have any IP addresses pre-configured for your use. You need
IP addresses for the following:
192.0.2.200/24 eth1 (cluster IP)
192.0.2.2/24 eth1 (testhost private IP)
192.168.4.120/24 eth0 (testhost external IP, which might vary)
When you run the nas-preconfig script, it reconfigures the server to the previous
settings. This step allows the SMU to recognize the server as the same and allows it to be
managed. Reconfigured settings:
IP addresses for Ethernet ports 0 and 1
Gateway
Domain name
Host name
On the replacement server:
Hitachi NAS Platform 3080 and 3090 G2 Hardware Reference
Labels
Note: Do not make any other cable connections at this time.
Appendix A: Server replacement procedures
Configuring the replacement server
Ports
Connections
3
Storage or FC switch
4
Storage or FC switch
0
Customer facing management network
1
Private management network