5
When installing the unit to the body, check that the grounding
spring is in contact with the TC/SC case (metal section) on the
rear and the front sides. (Visually check, and push the center of
the TC/SC unit to check that it can be moved up and down.)
Front
Front pawl
6
Transfer mylar lower
TC mylar lower
attachment reference
0~0.5
1.0 0.5
6. Process section
6-1. Process unit
1
Open the front cover, remove the developing unit, and open the
clamshell.
2
A
Remove process cover
. (Loosen the screw and release the
lock pawl to remove.)
3
Loosen two blue screws which are fixing the unit. Remove one
screw, disconnect one connector, and remove unit
hold the toner transport pipe.)
<Note> Remove the developing unit in advance.
B
Lock pawl
TCUN
Rear
Base plate
Rear pawl
1.5 0.5
B
. (Do not
A
Insert a screwdriver to
remove the lock pawl.
6-2. Waste toner bottle replacement (required when
waste toner full detection/maintenance)
1
Take out the process unit as shown above,
<Note> If the unit is removed by holding the toner transport pipe,
toner is spilled. Avoid this.
2
Remove the bottle cover. (2 screws)
3
Rotate waste toner bearing 1
Hole the base of toner transport pipe
time, toner may be spilled. Put a sheet under the pipe.
A
6 – 17
A
90 degrees counterclockwise.
B
and pull it out. (At this
B

Advertisement