Siemens SIMATIC MV550 S Operating Instructions Manual page 127

Table of Contents

Advertisement

Bit
2
3
4
5
6
7
The signals only work if "DISA = 1".
1)
Table 9- 34
Bit
0
1
2
3
4
5
6
7
SIMATIC MV500
Operating Instructions, 05/2019, C79000-G8976-C494-02
Signal
Description
SEL1
Select 1
1)
Program selection bit 1 (with TRN = 0) / save program (with TRN = 1)
SEL2
Select 2
1)
Program selection bit 2
SEL3
Select 3
1)
Program selection bit 3
TRN
Save program
1)
Saves new program.
TRG
Trigger
Processing starts on a positive edge.
RES
Reset
Reset error.
Assignment of status byte (output signals)
Signal
Description
IN_OP
In operation
0: Error message is displayed.
1: Optical reader functional, no error
TRD
Program saved
In run:
With Save program (TRN = 1)
RDY
Ready
0: Startup of the optical reader or optical reader in the "Stop"
1: Optical reader in "Start"
READ
Processing result
Code was localized and decoded.
MATCH
Processing result
Code matches the trained code.
N_OK
Code was not legible.
-
Current status of the trigger input
-
Reserved
Process interfacing via an automation system (PLC, PC)
0: Selected program is not saved.
1: Selected program has been saved.
0: Save program active
1: Acknowledgment signal (RDY = 0)
9.4 Control with FB 79
127