Service and maintenance
10.1 Error and diagnostics messages
Error code
Error message
(%c)
(%s)
0013
Nothing found
0014
Found m instead of the expected number of
1D/2D codes in step n
0015
Maximum number of codes per image (m) was
exceeded in step n
0016
The maximum amount of data which can be de-
coded was exceeded in code m of step n
0017
Trigger during image acquisition
0018
Step timeout reached in step n
1006
No text found in step n
1007
Text length is less than minimum specified in step
n
1008
Text length exceeds the maximum specified in
step n
1009
Quality violates limit values in step n
1010
Match failed in step n
1011
Reference text missing in step n
4700
Verification failed in step n
4701
Verification for code type found in step n not sup-
ported
4707
Mean light outside of range in step n: Maximum
exposure time reached
182
Description
In "Scan" or "Auto-trigger" mode (edge-controlled): All
image acquisitions were decoded without result.
Only m codes instead of the expected number of
codes were found in step # n during multicode decod-
ing.
More than the maximum possible number of codes
per image was found with multicode decoding (50,
MV500 U: 150).
A maximum of 3001 bytes can be decoded per step.
This length was exceeded in step #n for code #m.
The trigger signal was applied during image acquisi-
tion. In this case, no additional image acquisition is
started. Instead, image acquisition and processing are
continued and an "N_OK" result is generated immedi-
ately upon completion.
In step #n, the defined time limit was reached.
OCR: No text was found in step #n.
OCR: The text found in step #n is shorter than the
minimum setting.
OCR: The text found in step #n is longer than the
maximum setting.
OCR: The text found in step #n is below the quality
threshold setting.
OCR: The match performed in step #n was not suc-
cessful.
OCR: There is no string specification available for
step #n.
The read code could not be verified.
The selected verification method is not supported for
the code type found in step #n.
The average brightness needed for ISO/IEC 29158 is
outside the valid range (see Error code 4709).
The specified maximum value for the exposure time
was reached during automatic exposure control.
To resolve this error:
1. Use brighter lighting or enlarge the aperture of the
objective (lower aperture number).
2. Perform a new calibration.