Electrical System Maintenance; Maintaining The Battery - Toro 25450A Operator's Manual

Table of Contents

Advertisement

2. Rotate the battery-disconnect switch clockwise to the
On position; refer to
21).
3. Clean the fuel-pump head and the priming pump using
a quick-dry spray cleaner and compressed air
81).
Figure 81
1. Priming-pump handle
2. Fuel-pump head
4. Unlock the priming-pump handle by turning it
counterclockwise
(Figure
5. Pump the primer handle
resistance and the handle cannot be pumped anymore
(approximately 140 to 150 strokes for dry filters or 20
to 60 strokes for pre-filled filters).
6. Lock the manual priming pump handle by turning it
clockwise until it is fully seated
7. Start the engine; refer to
34).
Important: Do not engage the starter motor for
more than 10 seconds at a time. Allow 2 minutes
between cranking intervals.
Note: If the engine does not start after priming the
fuel system and making several attempts to start the
engine, bleed the high-pressure fuel lines; refer to your
engine owner's manual or contact your Authorized
Toro Service Dealer for assistance.
8. If the engine does not start, pump the priming pump
and repeat steps
4
through
Note: When the engine starts, it may run erratically
and louder than normal for a few minutes. This is
normal, as air is being purged from the system.
9. Operate the engine until it runs smoothly, then check
for any leaks.
Battery-Disconnect Switch (page
(Figure
3. Fuel/water separator
81).
(Figure
81) until you feel
(Figure
81).
Operating the Engine (page
7
until the engine starts.
Electrical System
Maintenance

Maintaining the Battery

Accessing the Battery
Remove the battery cover as follows:
1. Ensure that the battery-disconnect switch is in the Off
position; refer to
2. Remove the 2 finger-pull covers from the holes in the
battery cover.
3. Remove the 4 bolts that secures the battery cover to
the ROPS platform
Note: The battery cover is located between the
operator seat and the rear ROPS bulkhead.
1. Operator seat
2. Finger-pull cover
3. Hole (battery cover)
4. Using the finger pulls, lift the battery cover up to
remove it from the ROPS platform
Install the battery cover as follows:
1. Align the holes in the mounting flanges for the battery
cover with the plate nuts in the ROPS platform around
the battery
(Figure
2. Secure the battery cover to the ROPS platform with
the 4 bolts
(Figure
3. Install the 2 finger-pull covers into the holes of the
battery cover.
54
Battery-Disconnect Switch (page
(Figure
82).
Figure 82
4. Bolt
5. Nut clip
6. ROPS bulkhead
82).
82).