Chapter 3 Appendix
Error Message
B01D
Expansion ROM not
initialized - PCI
Slot 1D
B01A
Expansion ROM not
initialized - PCI
Slot 1A
B022
Serial Port Configuration
Overlapped.
B030
PCI System Error on
Bus/Device/Function
B040
PCI Parity Error on
Bus/Device/Function
B200
Onboard VGA – PCIe Link
Failure
B211
PCI Slot 1A - PCIe Link
Failure
B212
PCI Slot 1B - PCIe Link
Failure
B215
PCI Slot 1C - PCIe Link
Failure
B218
PCI Slot 1D - PCIe Link
Failure
B220
Onboard VGA – PCIe Link
Width Error
B231
PCI Slot 1A - PCIE Link Width
Error
B232
PCI Slot 1B - PCIE Link Width
Error
B235
PCI Slot 1C - PCIE Link Width
Error
B238
PCI Slot 1D - PCIE Link Width
Error
B260
Onboard VGA – PCIe Link
Speed Error
B271
PCI Slot 1A - PCIe Link Speed
Error
B272
PCI Slot 1B - PCIe Link Speed
Error
B275
PCI Slot 1C - PCIe Link Speed
Error
B278
PCI Slot 1D - PCIe Link Speed
Error
DXE_PCI_BUS_OUT_OF_RESOURCES
B800
C000
The error occurred during
fan sensor reading.
C010
The error occurred during
temperature sensor reading
C011
System Temperature out of
the range.
C020
The error occurred during
voltage sensor reading.
C021
System Voltage out of the
range.
192
Cause
Option ROM expansion in PCI slot
1D failed.
Option ROM expansion in PCI slot
1A failed.
Overlapping serial port
configuration was detected.
PCI SERR was detected.
PCI PERR was detected.
Connection failure of PCIe bus was
detected on Onboard VGA.
Connection failure of PCIe bus was
detected on PCI slot 1A.
Connection failure of PCIe bus was
detected on PCI slot 1B.
Connection failure of PCIe bus was
detected on PCI slot 1C.
Connection failure of PCIe bus was
detected on PCI slot 1D.
A Link Width error was detected on
Onboard VGA.
A Link Width error was detected in
PCI Slot 1A.
A Link Width error was detected in
PCI Slot 1B.
A Link Width error was detected in
PCI Slot 1C.
A Link Width error was detected in
PCI Slot 1D.
Link Speed error was detected on
Onboard VGA.
Link Speed error was detected on
PCI Slot 1A.
Link Speed error was detected on
PCI Slot 1B.
Link Speed error was detected on
PCI Slot 1C.
Link Speed error was detected on
PCI Slot 1D.
Resources to be allocated to PCI
expansion card was insufficient.
An error was detected while
reading fan sensor.
An error was detected while
reading temperature sensor.
A temperature abnormality was
detected.
An error was detected while
reading voltage sensor.
A system voltage abnormality was
detected.
Express5800/R120g-1E Maintenance Guide
1. POST Error Message
Solution
Disable expansion of option ROM of the
option board that is not used for OS boot.
Run SETUP, and select Advanced → PCI
Configuration → PCI Device Controller and
Option ROM Settings → PCIxx Slot Option
ROM → Disabled. (xx: PCI slot number)
Start SETUP, select Advanced → Serial Port
Configuration, and specify the setting again in
a way that the values of Base I/O or Interrupt in
Serial Port A and Serial Port B will not be the
same.
Contact your sales representative.
The cooling fan has failed or is clogged.
Contact your sales representative.
Contact your sales representative.