Chapter 3 Appendix
Error Message
C11B
BMC Mezzanine card is not
found.
C11C
BMC Mezzanine partition is
invalid.
BMC is in Forced Boot Mode. Detected that BMC is in Forced
C11D
Communication with BMC was
C11E
failed in previous boot
Backup Data of BMC Mezzanine
C11F
card has corrupted.
BMC Runtime FW corrupted.
C120
BMC Force Update FW corrupted. An error occurred on BMC Force
C121
BMC Configuration area
C122
corrupted.
BMC eMMC inaccessible.
C123
BMC eMMC mode error.
C125
BMC eMMC partition corrupted. An error occurred on BMC eMMC
C126
BMC eMMC format corrupted.
C127
BMC is in Update Mode.
C128
C300
Out-of-band setup
configuration failure
C301
SDR mismatch error
Hardware configuration
C302
error.
FAN Structure ID command
C303
error.
Necessary to update SDR
C304
Version for new RAID Card.
C310
Hardware configuration of
cooling is insufficient.
C320
Unmatched PSUs.
C321
System power consumption is
out-of-range in PSUs.
C322
No information for system
power consumption check.
Internal Use Area of BMC FRU is
C323
incompatible.
C501
Intel(R) Node Manager is in
Recovery Mode.
194
Cause
BMC Mezzanine card is not
installed.
A format error was detected in BMC
Mezzanine card.
Boot Mode.
Communication with BMC was
failed in previous boot
Inconsistency was found on BMC
mezzanine card.
An error occurred on BMC Runtime
FW.
Update FW.
An error occurred on BMC
Configuration area.
Failed to access to BMC eMMC.
BMC eMMC mode error occurred.
partition.
A format error occurred on BMC
eMMC.
BMC is in update mode.
An error was detected while
accessing BMC Mezzanine card.
Inconsistency in the hardware
information of the sensor data
record was detected.
Illegal hardware configuration was
detected.
Illegal fan control was detected
when RAID Controller is installed.
SDR for RAID Controller is
inappropriate.
Detected that cooling power is
insufficient in this hardware
configuration.
Unmatched power supply units are
configured.
System power consumption
exceeds the power output capacity
limit.
No information is acquired in
checking system power
consumption.
An incompatibility was detected in
FRU containing the device
information.
Intel(R) Node Manager is is
Recovery Mode.
Express5800/R120g-1E Maintenance Guide
1. POST Error Message
Solution
Contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on
motherboard. If the same error is detected
repeatedly, contact your sales representative.
Unplug the power cord, wait for 30 seconds,
and restart the server. If the same error is
detected repeatedly, contact your sales
representative.
Contact your sales representative.
Disconnect the power cord, wait for at least 30
seconds, and then restart the server. If the
same error is detected again, contact your
sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on
motherboard. If the same error is detected
repeatedly, contact your sales representative.