Lenovo ThinkSystem SD650 Manual page 133

Hide thumbs Also See for ThinkSystem SD650:
Table of Contents

Advertisement

Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0524
User Action:
Complete the following steps:
1. Please flash uEFI image to the latest level.
2. If the problem still exist, please remove and re-install CMOS battery for 30 seconds to clear CMOS
contents.
3. If the problem still exist, please contact local service.
• FQXSPUN0023N: Sensor [SensorElementName] has transitioned to non-recoverable.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
recoverable.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0530
User Action:
Complete the following steps:
1. Check the Lenovo support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reboot the system.
3. If problem persists, collect Service Data log and Contact Lenovo Support.
4. For 1-2 Processor system:
a. Reduce the compute board/system in error to a minimum configuration; 1 CPU + 1 DIMM. Does
the problem still occur? Yes/No
b. No: Add CPU and/DIMMs one and a time until the error re-occurs. Consider replacing the last
CPU or DIMM that was installed that caused the error.
c. Yes: If there error/problem still exists, swap in one of the other DIMMs and/or CPUs previously
removed in step a. Proceed to add HW one piece at a time to identify the bad CPU or DIMM.
d. If the problem still exist, (trained technician only) replace system board.
e. If problem persists, escalate to next level of support.
5. For 4-8 Processor system:
a. Escalate to a next level of support.
• FQXSPUN0026G: Device [LogicalDeviceElementName] has been added.
This message is for the use case when an implementation has detected a Device was inserted.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
.
Chapter 2
XClarity Controller events
129

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nextscale n12007x585468

Table of Contents