Severity
Warning
Serviceable
Automatically notify support
User Action
1. Make sure that FPC USB key is installed. Check if all power supplies are installed and in healthy
condition.
2. If all good, reconfigure power supply redundancy policy when needed.
• B2 : FAN01_No_Present
Indicated fan module is missing from fan bay or not properly installed.
Severity
Critical
Serviceable
Automatically notify support
User Action
1. Make sure that all ten fans are installed. If all fans are confirmed to be present, reseat fan
modules. If event persists after fan module reseat, replace fan modules.
• B3 : FAN02_No_Present
Indicated fan module is missing from fan bay or not properly installed.
Severity
Critical
Serviceable
Automatically notify support
User Action
1. Make sure that all ten fans are installed. If all fans are confirmed to be present, reseat fan
modules. If event persists after fan module reseat, replace fan modules.
• B4 : FAN03_No_Present
Indicated fan module is missing from fan bay or not properly installed.
Severity
Critical
Serviceable
Automatically notify support
User Action
1. Make sure that all ten fans are installed. If all fans are confirmed to be present, reseat fan
modules. If event persists after fan module reseat, replace fan modules.
• B5 : FAN04_No_Present
Indicated fan module is missing from fan bay or not properly installed.
Severity
238
ThinkSystem SD650 Dual Node DWC Tray and NeXtScale n1200 DWC Enclosure Messages and Codes Reference