Tank Model Paw-Vp1000/750Ldhw Combination With Vrf - Panasonic PRO-HT Tank Series Technical Manual

Table of Contents

Advertisement

Technical Data of Indoor Unit

1.1.3 Tank model PAW-VP1000/750LDHW combination with VRF

Heat Pump Model
Tank Model
1
Volume
Height×Diameter
Connections to the water supply network
Net weight / with water
Heat Pump
Nominal electrical power
Reference tapping cycle
Energy consumption by chosen cycle A7/W10-55 *
Energy consumption by chosen cycle A15/W10-55 *
COP DHW (A7/W10-55) EN16147
COP DHW (A15/W10-55) EN16147
Energy Effiency Class
Standby heat loss
Sound power/Sound pressure (Outdoor/evaporator unit)
Refrigerant
Refrigerant at shipment
Outdoor ambient operating range
Heating up time
VP tank DHW
Stainless steel 316L pickling/protective magnesium anode
Average insulation thickness
Internal exchanger (m² surface~connection)
Electrical specifications
Max power consumption without heater /with heater
Number of electrical heaters x power
Voltage / frequency
Electric protection heat pump /heaters
Moisture protection
Working pressure (storage tank / heat exchanger)
Domestic hot water preparation
Preparation with heat pump Min/Max water temperature
Preparation with electrical heater Min/Max water temperature
Refrigerant information
Refrigerant (R410A)
Refrigerant (R32)
- EN 16147:2017 - Heat pumps with electrically driven compressors.
Testing and requirements for making of domestic hot water units;
- Commission Delegated Regulation (EU) No. 812/2013 and Commission Regulation (EU) No. 814/2013.
* Mixed operating with heat recovery 100% outdoor unit ratio
22
For 100 % indoor outdoor ratio
according to EN16147 by using 3 Way system
according to EN16147 by using 3 Way system
for Energy Label; (EU) No. 812/2013 ANNEX III (A+–F)
for Product fiche: (EU) No. 812/2013 ANNEX II, Table1
U-16MF3E8
PAW-VP1000LDHW
L
933
mm
2210x990
RP 1 1/4"
kg
191 / 1124
kW
12
2XL
kWh
5.1
kWh
4.61
4.81
5.32
Not in the Scope of the regulation
W/h
80
dB/dB(A)
82/62
R410A
kg
8.3
°C
-20/+24
min
162
+/+
mm
100
4.0~1/2"–3/4"
kWh
20.4/26.4
W
1×6000
V/Hz
400/50
A
40/16
IP24
MPa(bar)
3.8 (38)
°C
5/65
°C
15/85
kg/TCO2 Eq
8.3/17.1
kg/TCO2 Eq
PAW-VP•LDHW - Technical Manual – 2020-07
U-16MF3E8
PAW-VP750LDHW
726
1855x990
RP 1 1/4"
179 / 905
12
2XL
4.14
3.5
5.29
7.01
77
82/62
R410A
8.3
-20/+24
133
+/+
100
3.4~1/2"–3/4"
20.4/26.4
1×6000
400/50
40/16
IP24
3.8 (38)
5/65
15/85
8.3/17.1

Advertisement