3.3.4 Capacity table PAW-VP750LDHW (18 °C)
3
42
City water inlet temp:
18 °C
Outdoor unit type:
U-250PE2E8A
PAW-VP750LDHW
Tank type:
Ambient
Water temp
temperature
WB
Set temp
45°C
+25°C
50°C
55°C
45°C
+20°C
50°C
55°C
45°C
+15°C
50°C
55°C
45°C
+12°C
50°C
55°C
45°C
+7°C
50°C
55°C
45°C
+2°C
50°C
55°C
45°C
+0°C
50°C
55°C
45°C
-2°C
50°C
55°C
45°C
-7°C
50°C
55°C
45°C
-10°C
50°C
55°C
45°C
-15°C
50°C
55°C
45°C
-20°C
50°C
55°C
• Based on peak cut setting 70%
• Please note: The data mentioned in this document is obtained by calculation.
Please use only for reference.
• Equivalent tubing length: 7,5 m, Difference of elevation: 0 m
Heating
Time
Capacity
[h:m:s]
[kWh]
2:18:45
22.96
27.67
3:00:00
3:43:15
30.81
2:23:23
22.96
3:06:00
27.67
3:50:42
30.81
2:14:53
22.96
2:54:59
27.67
3:37:01
30.81
2:17:39
22.96
2:58:35
27.67
3:41:29
30.81
22.96
2:14:53
2:54:59
27.67
3:37:01
30.81
22.96
2:38:10
3:25:12
27.67
4:14:30
30.81
2:39:40
22.96
3:27:09
27.67
4:16:55
30.81
2:38:52
22.96
3:26:05
27.67
4:15:36
30.81
2:42:04
22.96
3:30:15
27.67
30.81
4:20:47
2:44:46
22.96
3:33:45
27.67
4:25:07
30.81
2:49:15
22.96
3:39:34
27.67
4:32:20
30.81
2:53:44
22.96
3:45:24
27.67
4:29:33
30.81
Power Input
COP
[kWh]
9.23
2.49
11.97
2.31
14.85
2.08
9.53
2.41
12.37
2.24
15.34
2.01
8.97
2.56
11.64
2.38
14.43
2.13
9.15
2.51
11.88
2.33
14.73
2.09
8.97
2.56
11.64
2.38
14.43
2.13
10.52
2.08
13.65
2.03
16.92
1.82
10.62
2.16
13.78
2.01
17.09
1.80
10.56
2.17
13.70
2.02
17.00
1.81
10.78
2.13
13.98
1.98
17.34
1.78
10.96
2.01
14.21
1.95
17.63
1.75
11.26
2.04
14.60
1.90
18.11
1.70
11.55
1.99
14.99
1.85
1.86
1.66