Electrical Heater

11.3 Start-up and Service

11.3.1 Operation Keys and Displays

11
96
The heater and protecting box equipped with the temperature controller is a simple unit serving
to control the heating process. The unit controls the heater or set of the electric heaters which
are supplied from the power supply 230 V AC (1or 3 phase) or 400 V AC (3 phase).
The appearance and description of control push-buttons and information LEDs are shown below.
1
2
3
Number Name
Alarm-LED diode
1
Heating-LED diode
2
„–" push button
3
„+" push button
4
LED display
5
Connecting the TR-01 controller to supply voltage 230V/400V AC (depending on version)
causes switching on the informative screen with the current software version and then switching
off mode of the controller (OFF).
When in the OFF mode, the heating process is switched off. All heaters are disconnected from
the power supply. Pressing the push-button
controller to ON mode, and displays the current temperature. From this moment the process of
controlling heater/ heaters is activated.
Description
LED diode flashes, when alarm status is detected.
LED diode lights during heating. For 3-phase unit diode flashes 1°C
before the preset temperature.
Reduces the setting value or, if pressed for approximately 3 seconds –
changes the status of controller (ON/OFF) (see diagram page 99 ff. for
more information).
Increases the setting value or, if pressed for approximately 3 seconds –
moves to the menu for hysteresis change (ON/OFF) (see diagram page
99 ff for more information).
Displays the information on the current temperature, settings, alarms
and the status of the controller.
for approximately 3 seconds switches the