System drawings

6.1

System PACi DHW

Standard system 1:1
without water circulation
Standard system 1:1
with water circulation pipe*
External Pump control
example:
Water flow:
Qmin = 1 ltr./minute
Water pump operation
schedule:
At night: ON 15 min
Through the day:
For a hotel or apartment complex where the last room is more than 30 meters away from the
DHW tank, a water pump (for example type Grundfos comfort UP 15-14 BA PM) should be
installed in order to obtain hot water quickly.
Remember to install a return pipe pump circulation of maximum Ø15 mm and make sure that
supply and return pipes are well insulated to minimise heat loss.
PAW-VP•LDHW - Technical Manual – 2020-07
OFF 80 min
ON 15 min
OFF 40 min
Outdoor unit
Outdoor unit
System drawings
DHW
City
Water
in
DHW tank
City
Water
in
DHW tank
6
DHW
55