Excitation Ratio (Pr. 854) - Mitsubishi Electric FR-A720-00030-NA Instruction Manual

Table of Contents

Advertisement

Adjustment of Real sensorless vector
control, vector control
4.7.2

Excitation ratio (Pr. 854)

Decrease the excitation ratio when you want to improve efficiency under light load. (Motor magnetic noise
decreases.)
Parameter
Name
Number
854
Excitation ratio
 Note that the rise of output torque becomes slow if
excitation ratio is decreased.
This function is appropriate for applications as machine
tools which repeat rapid acceleration/deceleration up to
high speed.
REMARKS
 When "1" (magnetic flux with terminal) is set in Pr. 858 Terminal 4 function assignment or Pr. 868 Terminal 1 function assignment, the
Pr. 854 setting is invalid.
144
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Vector
Vector
Vector
Initial Value
Setting Range
100%
0 to 100%
Excitation
(initial value)
set value
Description
Set the excitation ratio under no load.
ratio [%]
100
Pr. 854
0
100
Load [%]

Advertisement

Table of Contents
loading

Table of Contents