Function assignment of external terminal and control
(1) Input terminal function assignment
 Use Pr. 178 to Pr. 189 to set the functions of the input terminals.
 Refer to the following table and set the parameters:
Signal
Setting
Name
Pr. 59 = 0 (initial value)
0
RL
Pr. 59 = 1 to 3
Pr. 270 = 1, 3, 11 or 13
Pr. 59 = 0 (initial value)
1
RM
Pr. 59 = 1 to 3
Pr. 59 = 0 (initial value)
2
RH
Pr. 59 = 1 to 3
Second function selection
3
RT
Pr. 270 = 1, 3, 11 or 13
4
AU
Terminal 4 input selection
5
JOG
Jog operation selection
Selection of automatic restart after instantaneous power failure,
flying start
6
CS
Commercial power supply-inverter switchover function
7
OH
External thermal relay input
15-speed selection (combination with three speeds RL, RM,
8
REX
RH)
9
X9
Third function selection
10
X10
Inverter run enable signal (FR-HC, MT-HC, FR-CV connection)
11
X11
FR-HC or MT-HC connection, instantaneous power failure detection Pr. 30, Pr. 70
12
X12
PU operation external interlock
13
X13
External DC injection brake operation start
14
X14
PID control valid terminal
15
BRI
Brake opening completion signal
PU/External operation switchover (turning ON X16 selects
16
X16
External operation)
Load pattern selection forward/reverse rotation boost (turning ON
17
X17
X17 changes the output characteristics to constant torque load)
18
X18
V/F switchover (V/F control is performed when X18 is on)
19
X19
Load torque high-speed frequency
20
X20
S-pattern acceleration/deceleration C switching terminal
22
X22
Orientation command
23
LX
Pre-excitation/servo on
Output stop
24
MRS
Commercial power supply-inverter switchover function
25
STOP
Start self-holding selection
26
MC
Control mode changing
27
TL
Torque limit selection
28
X28
Start-time tuning start external input
42
X42
Torque bias selection 1
43
X43
Torque bias selection 2
44
X44
P/PI control switchover (turning ON X44 selects P control)
50
SQ
Sequence start
Forward rotation command
60
STF
(assigned to STF terminal (Pr. 178) only)
Reverse rotation command
61
STR
(assigned to STR terminal (Pr. 179) only)
62
RES
Inverter reset
63
PTC
PTC thermistor input (assigned to AU terminal (Pr. 184) only)
64
X64
PID forward/reverse action switchover
65
X65
PU/NET operation switchover (turning ON X65 selects PU operation) Pr. 79, Pr. 340
External/NET operation switchover (turning ON X66 selects
66
X66
NET operation)
236
Function
Low-speed operation command
Remote setting (setting clear)
*1
Stop-on-contact selection 0
*2
Middle-speed operation command
Remote setting (deceleration)
*1
High-speed operation command
Remote setting (acceleration)
*1
Stop-on-contact selection 1
*2
*3
*4, *6
*5
*6
*6
Related Parameters
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Pr. 59
Pr. 270, Pr. 275, Pr. 276
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr.
232 to Pr. 239
Pr. 59
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Pr. 59
Pr. 44 to Pr. 51, Pr. 450 to Pr. 463,
Pr. 569, Pr. 832, Pr. 836, etc.
Pr. 270, Pr. 275, Pr. 276
Pr. 267
Pr. 15, Pr. 16
Pr. 57, Pr. 58, Pr.162 to Pr.165,
Pr. 299, Pr. 611
Pr. 57, Pr. 58, Pr.135 to Pr.139,
Pr. 159
Pr. 9
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr.232 to Pr.239
Pr. 110 to Pr. 116
Pr. 30, Pr. 70
Pr. 79
Pr. 10 to Pr. 12
Pr. 127 to Pr. 134, Pr. 575 to Pr. 577
Pr. 278 to Pr. 285
Pr. 79, Pr. 340
Pr. 14
Pr. 80, Pr. 81, Pr. 800
Pr. 270 to Pr. 274
Pr. 380 to Pr. 383
Pr. 350 to Pr. 369
Pr. 850
Pr. 17
Pr. 57, Pr. 58, Pr.135 to Pr.139,
Pr. 159
Pr. 800
Pr. 815
Pr. 95
Pr. 840 to Pr. 845
Pr. 840 to Pr. 845
Pr. 820, Pr. 821, Pr. 830, Pr. 831
Pr. 414 to Pr. 417, Pr. 498,
Pr. 506 to Pr. 515
Pr. 9
Pr. 127 to Pr. 134, Pr. 5
Pr. 79, Pr. 340
Refer to
Page
168
172
218
168
172
168
172
239
218
291
170
270
377
185
168
239
211
211
321
206
369
221
327
163
91, 147
382
178
224
206
238
377
240
91
99
202
113
113
104
367
240
240
185
369
328
328