Identical 16-Bit Data Block Transfers: Fmov - Mitsubishi Electric MELSEC Q Series Programming Manual

Motion controller
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

5 SEQUENCE INSTRUCTIONS FOR MOTION CPU

5.4.14 Identical 16-bit data block transfers: FMOV

Setting
data
X
Y
M
(S)
(D)
n
[Setting data]
[Function]
[Error]
Bit device
SM
F
T
C
D
[Instruction]
Command
FMOV
Setting data
Data to be transferred or the head number of the devices where the data
(S)
(D)
n
(1) Transfers 16-bit data at the device designated by (S) to n points of devices
starting from the one designated by (D).
(S)
The points specified in n exceed those of the corresponding device specified in (D),
sequence program error occurs.
Safety observation warnings (SM24) are turned ON and error code (SD32): 10, detail
code (SD33): 8010H are stored.
Usable device
Word device
W
T
C
SD
Z
FMOV
(S)
to be transferred is stored (BIN 16 bits)
Head number of the devices of transfer destination (BIN 16 bits)
Number of transfers (BIN 16 bits)
Transfer
0
5 - 47
Constant
Pointer
Level
K
H
P
N
(D)
n
Description
(D)
0
(D)+1
0
(D)+2
0
(D)+3
0
n
(D)+ (n-2)
0
(D)+ (n-1)
0
Digit
desig-
Index
nation
: Usable

Advertisement

Table of Contents
loading

Table of Contents