Questions And Troubleshooting; Power Supply; Cleave Operation - Fujitsu CT114 Instruction Manual

Large diameter optical fiber cleaver
Table of Contents

Advertisement

Questions and Troubleshooting

Power Supply

(1) Power does not turn on when pressing the ON/OFF key.
Press and hold the power button until the LED color changes to green.
(2) Power does not turn off when pressing ON/OFF key.
Pressing the button quickly will not turn off the cleaver. This is to prevent accidental
shutdown.
Press and hold the power button until the LED color changes from green to red.
(3) Machine times out and/or shuts down prematurely.
Refer to the [Machine Settings] section to change the power saving function parameters.

Cleave Operation

(1) Error Message appears on monitor.
Refer to the [Error Message List].
(2) Monitor suddenly turned off / No button response.
If the [Shut Down] function is enabled, the cleaver will turn the power off automatically
after an extended period of inactivity. Press and hold the ON/OFF key until the LED
color changes to green in order to turn the power back on.
(3) Initialize cleaving parameters.
Refer to [Checking or editing Cleave Mode].
(4) Unable to cleave.
Confirm that cleaver blade contacts the fiber during cleaving operation. If the blade does
not contact the fiber, execute the [Blade Adjustment] function in the [Maintenance
menu].
There is a possibility that tension is too low. Confirm that the fiber tension is appropriate
for the fiber diameter.
Dust or dirt may be on the insert and/or cleaver blade. Refer to [Daily Maintenance] and
[Loading Fiber into the Cleaver] section, and clean well.
The cleaver blade may be worn out. Execute [Blade Position Change] in the
[Maintenance Menu]. If all of the blade positions have been used, execute [Blade
Replacement] in the [Maintenance Menu].
CT114_Rev
2
76